Vue de la page 177
Run-time Error Messages
The table below lists the run-time error messages and some
basic solutions to the problems. Check the appropriate
section(s) in this appendix for other solutions.
Run-time error messages
Error
Countdown message
Number number Message
980 980 Unresolved memory
parity error
Solution
An installed SlMM has
failed; replace the SlMM
and run SETUP or the
ECU; contact your
dealer or servicer if the
problem persists
981
Memory parity error at
An installed SlMM has
nnnnmnnn
failed; replace the SlMM
and run SETUP or the
ECU; contact your
dealer or servicer if the
problem persists
982
I/O expansion board
Run the ECU; contact
NMI; dot n
your dealer or servicer if
the problem persists
983
Unresolved I/O
Run the ECU; contact
expansion board NMI
your dealer or servicer if
the problem persists
984
Expansion board
There is a configuration
disabled
error or the option card is
defective; run the ECU;
contact your dealer or
servicer if the problem
persists
985
Fail-safe timer NMI
The option card is
defective; replace the
card and run the ECU;
contact your dealer or
servicer if the problem
persists
A-14