REV.-A
0.47
*
0.02 mm
~-tl-
.—
Printhead
T\–
Platen
Fig. 4-34. Platen Gap
t Lever
Frame (Left side)
Carriage Guide
Shaft Lever (Left)
Fig. 4-35. Carriage Guide Shaft Lever Movement
Carriage guide shaft (left): Turned clockwise - The platen gap widens.
Turned counterclockwise -
The platen gap narrows.
Carriage guide shaft (right): Turned clockwise - The platen gap narrows.
Turned counterclockwise - The platen gap widens.
Perform the above adjustment at the 10th and 70th column positions, and at the middle of the platen.
When the gaps at all three positions match, the adjustment is complete.