Epson RC170 Guide de l'utilisateur

Naviguer en ligne ou télécharger Guide de l'utilisateur pour Imprimer et scanner Epson RC170. Epson RC170 User`s guide Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 312
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs

Résumé du contenu

Page 1 - User's Guide

Rev.4 EM12XS2357FEPSON RC+ 5.0 User's Guide Project Management and Development Ver.5.4

Page 2

Table of Contents 3. Getting Started 23 3.1 Hardware Installation ... 23 3.2 S

Page 3

5. The EPSON RC+ 5.0 GUI 82 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Execute Motion Group This group has controls for executing motion comman

Page 4 - WARRANTY

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 83 To change a jog distance, first select the distance to be changed, the

Page 5

5. The EPSON RC+ 5.0 GUI 84 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 To jog Select the jog mode: World, Tool, Local, Joint, or ECP. Select t

Page 6 - SUPPLIERS

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 85 Saving or aborting your work Click the Save button on the Robot Manage

Page 7

5. The EPSON RC+ 5.0 GUI 86 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Tools: Robot Manager: Arch Page This page allows you to configure the de

Page 8

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 87 Tools: Robot Manager: Locals Page This page allows you to define local

Page 9 - TABLE OF CONTENTS

5. The EPSON RC+ 5.0 GUI 88 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Using the Local Wizard A wizard is provided for defining a local coordin

Page 10 - 4. Operation 24

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 89 4. We will now teach the local origin point. Click the Teach button

Page 11

5. The EPSON RC+ 5.0 GUI 90 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Using the Local Wizard to teach a three point local 1. Open the Robot M

Page 12

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 91 4. We will now teach the local origin point. Click the Teach button

Page 13 - 6 The SPEL+ Language 150

Table of Contents 5.6.7 Restore Command ... 43 5.6.8 Rename Command ...

Page 14

5. The EPSON RC+ 5.0 GUI 92 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 7. We will now teach a point on the local Y axis. Click the Teach butt

Page 15 - xiii

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 93 Tools: Robot Manager: Tools Page This page allows you to define tool s

Page 16 - 10 Inputs and Outputs 246

5. The EPSON RC+ 5.0 GUI 94 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Using the Tool Wizard 1. Open the Robot Manager and click on Tools to s

Page 17

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 95 5. Jog the robot until the tool is aligned with the reference point.

Page 18 - Table of Contents

5. The EPSON RC+ 5.0 GUI 96 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Tools: Robot Manager: Arms Page This page allows you to define Arm setti

Page 19 - 1. Introduction

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 97 Tools: Robot Manager: ECP Page This page allows you to define ECP (ext

Page 20 - 1.2.4 Simulator

5. The EPSON RC+ 5.0 GUI 98 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Tools: Robot Manager: Box Page When the RC180 Controller firmware is Ver

Page 21 - 1.2.5 System Block Diagram

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 99 Tools: Robot Manager: Plane Page When the RC180 Controller firmware is

Page 22 - 1.3 Software Version

5. The EPSON RC+ 5.0 GUI 100 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Tools: Robot Manager: Weight Page This page is for changing the Weight

Page 23

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 101 Tools: Robot Manager: Inertia Page This page is for changing the Iner

Page 24 - 1.3.1 Version Confirmation

Table of Contents 5.10.5 Walk Command ... 75 5.10.6 Resume Command ...

Page 25

5. The EPSON RC+ 5.0 GUI 102 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Tools: Robot Manager: XYZ Limits Page This page allows you to configure

Page 26

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 103 Tools: Robot Manager: Range Page This page allows you to configure th

Page 27 - 1.7 SPEL for Windows Users

5. The EPSON RC+ 5.0 GUI 104 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Tools: Robot Manager: Home Config Page Home Config allows you to config

Page 28 - 1.8 Documentation

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 105 5.11.2 Task Manager Command (Tools Menu) The Task Manager window al

Page 29 - 2. Safety

5. The EPSON RC+ 5.0 GUI 106 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Item Description Halt Suspends the selected task. This temporarily st

Page 30 - 2.2.4 Start Mode

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 107 5.11.3 I/O Label Editor Command (Tools Menu) The I/O label editor l

Page 31 - 2.2.7 Teach Control Device

5. The EPSON RC+ 5.0 GUI 108 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 To add or edit a label Select the type of I/O you want to label in the

Page 32

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 109 5.11.4 I/O Monitor Command (Tools Menu) The I/O Monitor window lets

Page 33

5. The EPSON RC+ 5.0 GUI 110 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 To view bytes and words in hexadecimal format, check the Hexadecimal Va

Page 34

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 111 5.11.5 Command Window Command (Tools Menu) The command window emulat

Page 35

Table of Contents 5.11.9 Simulator Command...118 5.11.10 Vision Command ...

Page 36

5. The EPSON RC+ 5.0 GUI 112 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Key Action Ctrl+V Execute Paste command. Paste from Clipboard to curre

Page 37

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 113 5.11.7 Controller Command (Tools Menu) Select Controller from the To

Page 38 - 2.5.3 Teaching Robot Points

5. The EPSON RC+ 5.0 GUI 114 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Restore Controller Use Restore Controller to load controller settings f

Page 39 - 2.5.7 Maintenance

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 115 5. Click the <OK> button to restore the system information. Re

Page 40 - 2.7 End User Training

5. The EPSON RC+ 5.0 GUI 116 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 View Controller Status Click the View Controller Status button to view

Page 41 - 3. Getting Started

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 117 Reset Controller Use Reset Controller to reset the current controller

Page 42 - 4. Operation

5. The EPSON RC+ 5.0 GUI 118 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 5.11.9 Simulator Command (Tools Menu) This command opens the Simulato

Page 43 - 4.3.3 Start Mode

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 119 5.12.1 PC to Controller Communications Command (Setup Menu) The PC

Page 44 - 4.3.5 Start Mode: Program

5. The EPSON RC+ 5.0 GUI 120 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 5.12.2 Controller Command (Setup Menu) The Controller command opens t

Page 45 - 4.3.7 Auto Start

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 121 Setup: Controller: Configuration Page This page allows the user to vi

Page 46 - 4.3.9 Command Line Options

Table of Contents 6.2 Program structure ... 151 6.2.1 What is a SPEL+ program

Page 47

5. The EPSON RC+ 5.0 GUI 122 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Setup: Controller: Preferences Page This page contains controller pref

Page 48 - 4.4.2 USB Communications

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 123 Include project files in when status exported This preference allows

Page 49

5. The EPSON RC+ 5.0 GUI 124 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Setup: Controller: Options This page is used to configure options in th

Page 50

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 125 Setup: Controller: Robot Setup: Controller: Robot Model Page Use this

Page 51

5. The EPSON RC+ 5.0 GUI 126 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Setup: Controller: Robot Configuration Page Item Description Name Ente

Page 52 - Function main

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 127 Setup: Controller: Robot Calibration Page You can calibrate each joi

Page 53 - 08:24:18 All tasks stopped

5. The EPSON RC+ 5.0 GUI 128 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Setup: Controller: Robot Amplifiers Page This page shows the power valu

Page 54

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 129 Setup: Controller: Remote Control Inputs Page Use this page to config

Page 55

5. The EPSON RC+ 5.0 GUI 130 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Setup: Controller: Remote Control Outputs Page Use this page to configu

Page 56 - 5. The EPSON RC+ 5.0 GUI

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 131 Setup: Controller: Remote: Ethernet Use this page to configure the Re

Page 57 - 5.3 Status Window Pane

Table of Contents 6.17.5 Saving and loading Points... 178 6.17.6 Point attributes ...

Page 58 - 5.5 Online Help

5. The EPSON RC+ 5.0 GUI 132 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Setup: Controller: Remote: RS232 Use this page to configure the Remote

Page 59 - 5.6 File Menu

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 133 Setup: Controller: RS232 Pages There is one page for each RS232 port

Page 60

5. The EPSON RC+ 5.0 GUI 134 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 4. Change the other settings as desired. 5. Click Apply to save the n

Page 61

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 135 Setup: Preferences: Startup: Auto Start Page Item Description Start

Page 62

5. The EPSON RC+ 5.0 GUI 136 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Setup: Preferences: Startup: Windows Login Page The Windows Login page

Page 63

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 137 Setup: Preferences: Workspace Page From this page, you can configure

Page 64

5. The EPSON RC+ 5.0 GUI 138 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Setup: Preferences: Editor Page This page is used to configure your pre

Page 65 - 5.7 Edit Menu

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 139 Setup: Preferences: Robot Manager: General Page This page lets you co

Page 66

5. The EPSON RC+ 5.0 GUI 140 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Setup: Preferences: Robot Manager: Jogging Page This page lets you conf

Page 67

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 141 Setup: Preferences: Run Window Page This page allows you to change pr

Page 68

Table of Contents 7.5.2 Debugging ... 199 7.6 The Operator Window...

Page 69 - 5.8 View Menu

5. The EPSON RC+ 5.0 GUI 142 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Setup: Preferences: Command Window Page This page allows you to change

Page 70

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 143 Setup: Preferences: Language This page allows you to change the EPSO

Page 71 - 5.9 Project Menu

5. The EPSON RC+ 5.0 GUI 144 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 5.13 Window Menu The Window Menu contains selections for managing the

Page 72

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 145 5.13.3 Tile Vertical Command (Window Menu) Use Tile Vertical to even

Page 73

5. The EPSON RC+ 5.0 GUI 146 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 5.13.6 1, 2, 3 Command (Window Menu) A list of currently open documen

Page 74

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 147 5.14 Help Menu The Help Menu contains selections for accessing the

Page 75

5. The EPSON RC+ 5.0 GUI 148 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 5.14.3 Index Command (Help Menu) This command opens the Index view fo

Page 76

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 149 5.14.5 Manuals Submenu (Help Menu) The Help Menu Manuals submenu co

Page 77

6. The SPEL+ Language 6. The SPEL+ Language This chapter contains information about the SPEL+ Language. Contents - Overview - Program structure - Co

Page 78

6. The SPEL+ Language 6.1 Overview SPEL+ is a BASIC-like programming language that runs in the controller. It supports multitasking, motion contro

Page 79

Table of Contents 10.5 Virtual I/O... 247 11 Remote Control 248

Page 80

6. The SPEL+ Language 6.3 Commands and statements Commands and statements consist of a SPEL+ instruction followed by the parameters for that instru

Page 81

6. The SPEL+ Language 6.5 Data types You can declare different types of data in your program. All variables must be declared. The following table

Page 82

6. The SPEL+ Language 6.7 Working with variables 6.7.1 Variable scopes There are three different scopes for variables in SPEL+: - Local - Module

Page 83

6. The SPEL+ Language 6.7.4 Global variables Global variables can be shared between all functions in a project. The Global instruction is used to

Page 84

6. The SPEL+ Language 6.7.6 Arrays You can declare local, module, and global arrays with up to three dimensions for all data types. To declare an a

Page 85

6. The SPEL+ Language 6.8 Working with strings A string in SPEL+ is a set of ASCII characters with a maximum length of 255. You must declare string

Page 86

6. The SPEL+ Language 6.9 Multi-statements A program statement can contain several statements separated by semi-colons. The total length of a mult

Page 87

6. The SPEL+ Language 6.12 Error handling When an error occurs in a SPEL+ function, you can cause execution to be transferred to an error handling

Page 88

6. The SPEL+ Language Example The following example shows a simple error handling routine. When an error occurs, program execution goes to the ErrHa

Page 89

6. The SPEL+ Language 6.13 Multi-tasking For some applications, you may want to control other equipment besides the robot, such as conveyors, pick

Page 90

Table of Contents xvi EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4

Page 91 - Project: Properties: Vision

6. The SPEL+ Language 6.14 Robot coordinate systems 6.14.1 Overview In this section we discuss the coordinate systems for different types of robo

Page 92 - 5.10 Run Menu

6. The SPEL+ Language Robot Coordinate Systems for 6-Axis Robot Floor Mounting Ceiling Mounting S ide (Wall) Mounting EPSON RC+ 5.0 (Ver.5.4)

Page 93

6. The SPEL+ Language Robot Coordinate Systems for RS series Origin Y+X+ View from this direction Robot coordinate system Z axis Robot coordinate

Page 94

6. The SPEL+ Language 6.14.3 Local Coordinate Systems With SPEL+, a maximum of 15 local coordinate systems can be defined. SPEL+ correlates robot

Page 95

6. The SPEL+ Language 6.14.5 ECP Coordinate Systems (Option) Specify a coordinate system whose origin point is on the tip of the outside fixed tool

Page 96 - 5.11 Tools Menu

6. The SPEL+ Language 6.15 Robot arm orientations When developing a robot a program, it is necessary to specify the point data taught for a particu

Page 97

6. The SPEL+ Language 6.15.2 6-Axis robot arm orientations The 6-Axis robot can be operated in various arm orientations within a given work envelop

Page 98

6. The SPEL+ Language To specify orientation for the 6-Axis robot, add a forward slash (/) followed by L (for Lefty hand orientation) or R (Righty ha

Page 99

6. The SPEL+ Language PTP motion near the singularity When jogging a robot from a point near the singularity to a point calculated by point operati

Page 100

6. The SPEL+ Language LJM function for CP motion command LJM function and AutoLJM command described above are also available for CP motion commands.

Page 101

1. Introduction EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 1 1. Introduction 1.1 Welcome to EPSON RC+ 5.0 Welcome to the EPSON RC+ 5.0 Pro

Page 102

6. The SPEL+ Language 6.15.3 RS series arm orientations The RS series can be operated in various arm orientations within a given work envelope as

Page 103

6. The SPEL+ Language To specify orientation for the RS series, add a forward slash (/) followed by L (for Lefty hand orientation) or R (Righty hand

Page 104

6. The SPEL+ Language 6.16 Robot motion commands SPEL+ includes several commands for controlling the robot from your programs. 6.16.1 Homing the

Page 105

6. The SPEL+ Language 6.16.5 Joint motion Command Description JTran The JTran command can be used to move one joint of the robot to positionspecifie

Page 106

6. The SPEL+ Language 6.16.8 PTP Speed / Acceleration for Small Distances You can change the speed and acceleration for small distances using PTPBo

Page 107

6. The SPEL+ Language 6.17 Working with robot points A robot point is a set of coordinates that define a position in the robot work envelope. For

Page 108

6. The SPEL+ Language 6.17.4 Using points in a program When starting programs, the default point file for the robot is loaded. You can also load ot

Page 109

6. The SPEL+ Language Elbow point attribute To specify elbow orientation for the 6-Axis robot in a point assignment statement, add a forward slash (/

Page 110

6. The SPEL+ Language 6.17.7 Extracting and setting point coordinates Use the CX, CY, CZ, CU, CV, and CW commands to get a coordinate of a point or

Page 111

6. The SPEL+ Language 6.18 Input and output control 6.18.1 Hardware I/O There are 24 DC inputs and 16 DC outputs on a standard controller. 8 inp

Page 112

EPSON RC+ 5.0 (Ver.5.4) User's Guide Project Management and Development Rev.4

Page 113

1. Introduction 2 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 1.2.1 RC180 Controller The RC180 Controller is a compact robot controller that c

Page 114

6. The SPEL+ Language 6.19 Using Traps Traps are used to cause program execution to jump to a label or enable a function to be called or executed a

Page 115

6. The SPEL+ Language 6.20 Special Tasks Each task of SPEL+ pauses by Pause input or Safety Door open and stops by Emergency Stop or Error. There

Page 116

6. The SPEL+ Language Outputs off during Emergency Stop Uncheck Outputs off during Emergency Stop in the Preferences page of Setup Controller to ex

Page 117

6. The SPEL+ Language EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 185 Task Exection Normal Omit the task type in Xqt statement, or specify Norma

Page 118

7. Building SPEL+ Applications 7. Building SPEL+ Applications 7.1 Designing Applications 7.1.1 Creating the simplest application The simplest S

Page 119 - 101

7. Building SPEL+ Applications Operators can select from 1 to 8 programs that you specify. They can also optionally use the I/O Monitor, Robot Manag

Page 120

7. Building SPEL+ Applications 7.2 Managing Projects 7.2.1 Overview What is an EPSON RC+ 5.0 Project? An EPSON RC+ 5.0 project is a collection of

Page 121 - 103

7. Building SPEL+ Applications 7.2.2 Creating a new project Projects can be created on any drive on your system. Projects always reside in the \Ep

Page 122

7. Building SPEL+ Applications 7.2.4 Building a project Before you can run any of the code in your application, you must build the project. To bui

Page 123 - 105

7. Building SPEL+ Applications 7.2.5 Making copies of projects Use the Copy Project command in the Project Menu to copy all of the files in the cur

Page 124

1. Introduction EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 3 1.2.5 System Block Diagram The following system block diagram shows different

Page 125 - 107

7. Building SPEL+ Applications 7.3 Editing Programs Before you can edit a program, it must be in the current project and opened in a program editor

Page 126

7. Building SPEL+ Applications 7.3.3 Syntax Help When you type in a SPEL+ keyword or user function, the syntax help window will appear to show the

Page 127 - 109

7. Building SPEL+ Applications 7.3.4 Syntax Errors When a syntax error is detected, the line with the error will be displayed in red. If the caret

Page 128

7. Building SPEL+ Applications 7.4 Editing Points EPSON RC+ 5.0 provides a spreadsheet editor for robot points. You can define new points or cut,

Page 129 - 111

7. Building SPEL+ Applications Wrist column Drop down list with two values for robot wrist orientation: Flip and NoFlip. This column is shown only

Page 130

7. Building SPEL+ Applications 7.5 Running and Debugging Programs You can run programs from the Run Window or from the Operator Window. The Run Wi

Page 131 - Backup Controller

7. Building SPEL+ Applications Item Description Text area This is the area that takes up most of the run window. Output from your programs is displ

Page 132 - Restore Controller

7. Building SPEL+ Applications 7.5.2 Debugging EPSON RC+ 5.0 supports source level debugging. You can set breakpoints and step through your source

Page 133 - Export Controller Status

7. Building SPEL+ Applications Stepping through a program There are three commands on the Run Menu that are used for stepping through code. Step In

Page 134 - View Controller Status

7. Building SPEL+ Applications After you select a function in the Call Stack list, the function will be displayed in a program window and an arrow in

Page 135 - Reset Controller

1. Introduction 4 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 1.3 Software Version There are the following major software versions for EPSONRC

Page 136 - 5.12 Setup Menu

7. Building SPEL+ Applications 2. Select Display Variables from the Run Menu to display the variable display dialog. This dialog has three tabs for

Page 137 - 119

7. Building SPEL+ Applications 7.6 The Operator Window The Operator Window can be used as a simple interface for operators. You can configure EPSO

Page 138

7. Building SPEL+ Applications 7.6.1 Operator Window Configuration You can configure the Operator Window from the Operator Window pages in Project

Page 139 - 121

8. Simulator 8. Simulator 8.1 Simulator Functions Simulator functions enable easy robot motion checking on your PC, which gives you flexibility t

Page 140

8. Simulator 8.1.2 System Requirements Recommended specification When using CAD data, we recommend using a PC running Windows 7 Professional 32 bi

Page 141 - 123

8. Simulator 8.2 Using the Simulator You can try the simulation functions using the provided sample virtual controllers and projects. See section

Page 142 - Setup: Controller: Simulator

8. Simulator (3) Click the <Open> button. Then, the following program window appears. 3. Display the simulator window Click the Tool bar-&

Page 143 - Setup: Controller: Robot

8. Simulator 4. Operate the robot by executing program (1) Click the Tool bar-<Run Window > button. The project will be built and the [Run

Page 144

8. Simulator Click the <Add> button. (2) The [New Controller Connection] dialog appears. Select the <Connection to new virtual controlle

Page 145 - 127

8. Simulator 3. Configure a robot In this tutorial, a G6-551S robot model is used. (1) Select the EPSON RC+ 5.0 menu-[Setup]-[Controller]. (2)

Page 146

1. Introduction EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 5 You can connect a controller and PC with any major version combinations. RC180 C

Page 147 - 129

8. Simulator 5. Place the objects For this tutorial, we will add a box to the layout. (1) Drag & drop the <Box > button on the Tool ba

Page 148

8. Simulator (2)-3 Select the [Jog & Teach] tab. The following window appears. (2)-4 In the [Robot Simulator] window, move the robot joint t

Page 149 - CAUTION

8. Simulator 7. Operate the robot by executing program (1) Click the Tool bar-<Run Window> button. The following dialog appears. (2) Cli

Page 150

8. Simulator (5) Select “main2” in the [Function] dropdown list. (6) Click the <Start> button. The message “Are you ready to start?” appears

Page 151 - 133

8. Simulator 8.3 Description of Functions This section describes how to use the simulator window and its functions. 8.3.1 Simulator window layou

Page 152 - Setup: Preferences: Startup

8. Simulator Button Description Create Movie Plays a simulation result (log file) in the Playback mode and savesinto a movie file. A dialog appears

Page 153 - 135

8. Simulator (3) Property Grid Pane In the Property Grid pane, you can view and change the settings of the robot objects and layout objects in the L

Page 154

8. Simulator Check Self Collision Enables / disables the collision detection for a robot itself. Enable : True (default) Disable : False Changing

Page 155 - 137

8. Simulator Points Display the point display setting status in the point file. Switch to show/non-show all points. Property Description File Name

Page 156

8. Simulator Hand When a hand is registered with a robot, “Hand” is added in the Layout Objects tree. Property Value Name Hand name You can speci

Page 157 - 139

1. Introduction 6 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 1.3.1 Version Confirmation To confirm the EPSON RC+ 5.0 version, refer to 5.14.6

Page 158

8. Simulator ◆ Layout Object Layout Box / Layout Sphere / Layout Cylinder / Layout Plane / CAD There are common attributes for all objects and other

Page 159 - 141

8. Simulator Height Cylinder Plane Cylinder height Floor length / Wall height Width Plane Floor width / Wall width Rotation All Object angle

Page 160

8. Simulator Change layout object color When you want to change layout object color, click on the drop-down in the Color property and the dialog sho

Page 161 - Setup: Preferences: Language

8. Simulator (4) 2D Layout In the [2D Layout] panel, you can add layout objects, or modify and check the robot objects and layout objects positions.

Page 162 - 5.13 Window Menu

8. Simulator (5) 3D Display In the 3D display, you can check the robot orientation and motion from various points of view. Change the robot / layo

Page 163 - 145

8. Simulator Check for collisions When a collision between a robot and layout object is detected, the collided robot joint and layout object are disp

Page 164

8. Simulator (6) Record / Playback In Playback mode, you can record and produce simulation results. Also, you can store the simulation results in m

Page 165 - 5.14 Help Menu

8. Simulator 8.3.2 Simulator Settings When you click the Tool bar-<Simulator Settings > button, the [Simulator Settings] dialog appears.

Page 166

8. Simulator Produce the robot motion by outputting to a recording file (1) Confirm that the mode is “Simulation” mode on the Simulator Tool bar.

Page 167 - 149

8. Simulator 8.3.3 Collision detection In the simulation, collisions can be detected between the robots including its hand and the layout objects.

Page 168 - 6. The SPEL+ Language

1. Introduction EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 7 EPSON RC+ 5.0 Ver.5.2.* or later / Controller firmware Ver.1.6.*.* or later RC18

Page 169 - 6.2 Program structure

8. Simulator It cannot guarantee that it has enough time for robots to stop when the simulator detects the collision. Caution about the collision de

Page 170 - 6.3 Commands and statements

8. Simulator (4) New “Virtual 2” is created. Click the <Apply> button. (5) Close the dialog and go back to the EPSON RC+ 5.0 main window.

Page 171 - 6.6 Operators

8. Simulator Enable the Simulator in controller From the [Setup]-[Controller]-[Simulator], check the [Enable Simulator] check box to enable the simu

Page 172 - 6.7 Working with variables

8. Simulator 8.4 Simulator Specifications and Restrictions This section describes the simulator specification, its restrictions, and precautionary

Page 173 - 6.7.4 Global variables

8. Simulator CAD data setup orientation Some CAD data coordinates may be different from those of the simulator. Adjust the coordinates to the corre

Page 174 - 6.7.8 Clearing arrays

8. Simulator Collision Detection Precision The Simulator Collision Detection provides an indication whether robots collide with the peripheral equip

Page 175 - 6.8 Working with strings

8. Simulator 8.4.4 Specification and precaution of EPSON RC+ Restriction on the controller settings When you connect with a virtual controller, t

Page 176 - 6.11 Comments

8. Simulator (3) Ethernet / RS-232C communication command (Print #, Input #, OpenCom, OpenNet, etc.) All ports including the option RS-232C board a

Page 177 - 6.12 Error handling

8. Simulator (4) Vision command (VRun, VGet, etc.) For Vision-related commands, the communication with Smart Camera (SC300 / SC1200) is not performe

Page 178

9. Robot Configuration EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 241 9. Robot Configuration This chapter contains information for configuri

Page 179 - 6.13 Multi-tasking

1. Introduction 8 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 EPSON RC+ 5.0 Ver.5.4.* or later / Controller firmware Ver.1.10.*.* or later RC18

Page 180 - 6.14.1 Overview

9. Robot Configuration 242 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 9.2 Calibrating the Robot EPSON RC+ 5.0 provides a calibration wizard fo

Page 181

9. Robot Configuration EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 243 7. For SCARA robots, reset the encoder for the selected joint as descr

Page 182

9. Robot Configuration 244 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 13. Click the Next button to view the next step. 14. Click the Finish bu

Page 183

9. Robot Configuration EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 245 9.3 Changing Robot System Parameters The following system parameters f

Page 184 - Outside Fixed Tool

10. Inputs and Outputs 246 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 10. Inputs and Outputs 10.1 Overview The RC90/RC180 controller I/O has

Page 185 - 6.15 Robot arm orientations

10. Inputs and Outputs EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 247 10.3 I/O Configuration To view the current I/O configuration, select S

Page 186

11. Remote Control 248 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 11. Remote Control 11.1 Overview The controller can be controlled by exter

Page 187

11. Remote Control EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 249 11.2 Remote Control Input Output Configuration This is the procedure to as

Page 188 - Proper motion

11. Remote Control 250 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 11.4 Auto Mode with Remote Control To run in auto cycle with remote control

Page 189

11. Remote Control EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 251 11.7 Remote Inputs Remote inputs are used to control the Manipulators and

Page 190

1. Introduction EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 9 1.4 Options You can purchase options that must be enabled in the controller.

Page 191

11. Remote Control 252 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Function SelProg1 SelProg2 SelProg4 Main 0 0 0 Main1 1 0 0 Main2 0 1 0 Main3

Page 192 - 6.16 Robot motion commands

11. Remote Control EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 253 11.8 Remote Outputs Remote outputs provide status for the Manipulator and

Page 193 - 6.16.5 Joint motion

11. Remote Control 254 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 (*1) Outputs the current or the last function number of CurrProg1, CurrProg2,

Page 194

11. Remote Control EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 255 11.9 Remote Input Handshake Timing The following charts indicate the timin

Page 195 - 6.17.1 Defining points

11. Remote Control 256 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Timing Diagram for Safety Door Input Sequence 8 1052 1052 500 9 11 11 928

Page 196 - 6.17.6 Point attributes

11. Remote Control EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 257 11.10 Remote Ethernet Remote Ethernet makes it possible to control the ro

Page 197

11. Remote Control 258 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Set the remote control available by the following procedure. (1) Connect fro

Page 198 - 6.17.8 Alteration of points

11. Remote Control EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 259 Remote command Format: $ remote command {, parameter...} terminator Remot

Page 199 - 6.18.3 I/O Commands

11. Remote Control 260 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Remote command Parameter Contents Input acceptance condition (*1) SetIOWord

Page 200 - 6.19 Using Traps

11. Remote Control EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 261 (*1) The Controller state bit from GetStatus. (*2) Execute the function s

Page 201 - 6.20 Special Tasks

1. Introduction 10 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 1.8 Documentation All documentation is installed on the PC in Adobe PDF format.

Page 202

11. Remote Control 262 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 (*9) Specify the command and parameters in the double quotation marks. Foll

Page 203

11. Remote Control EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 263 Response When the Controller receives the command correctly, the response i

Page 204 - 7.1 Designing Applications

11. Remote Control 264 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Flag Contents Warnig Turn ON in the warning condition Task can be executed a

Page 205 - Peripherals

11. Remote Control EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 265 Error response When the Controller can not receive the remote command corre

Page 206 - 7.2 Managing Projects

11. Remote Control 266 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 11.11 Remote RS232 Remote RS232 makes it possible to control the robot and c

Page 207 - Editing a project

11. Remote Control EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 267 For the details of the dialog setting, refer to the section 5.12.2 Control

Page 208 - Status Pane

11. Remote Control 268 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 CAUTION  If you set “0” in the [Timeout] box, time out duration is infinite

Page 209 - 7.2.6 Backing up a project

11. Remote Control EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 269 Remote Command Send command Data Description Input Acceptance Condition (*

Page 210 - 7.3 Editing Programs

11. Remote Control 270 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Remote Command Send command Data Description Input Acceptance Condition (*1)

Page 211 - 7.3.3 Syntax Help

11. Remote Control EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 271 Remote Command Send command Data Description Input Acceptance Condition (*

Page 212 - 7.3.4 Syntax Errors

2. Safety EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 11 2. Safety 2.1 Overview This chapter explains the important safety requirements for

Page 213 - 7.4 Editing Points

11. Remote Control 272 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 For the backup parameters when the parameter name and type are same. (*7) Fo

Page 214

11. Remote Control EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 273 Commands available for monitoring When the Remote RS232 control is not set

Page 215 - 7.5.1 The Run Window

11. Remote Control 274 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Command Format GetIOMemWord [ACK] ‘u’[ Word value(16Bit) (&H0000~&HFF

Page 216

11. Remote Control EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 275 Flag Contents Paused Turn ON with paused task Running Turn ON with task ex

Page 217 - 7.5.2 Debugging

11. Remote Control 276 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Communication sequence 180Controller Port xx RS-232C RemoteController

Page 218

12. RS-232 Communications EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 277 12. RS-232 Communications The RC180 controllers can support up to 8

Page 219

12. RS-232 Communications 278 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 12.2 RS-232 Commands Here is a list of all of the commands associated

Page 220

13. TCP / IP Communications EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 279 13. TCP / IP Communications EPSON RC+ 5.0 supports eight TCP/IP p

Page 221 - 7.6 The Operator Window

13. TCP / IP Communications 280 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 13.1.4 Testing Windows TCP/IP setup Use the ping command from a Com

Page 222 - 7.7 Using Remote Control

13. TCP / IP Communications EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 281 13.2 TCP/IP Software Configuration You can configure TCP/IP setti

Page 223 - 8. Simulator

EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Copyright © 2011-2012 SEIKO EPSON CORPORATION. All rights re

Page 224

2. Safety 12 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 2.2.2 Safeguard To ensure safe operation of the robotic work cell, you must install a

Page 225 - 8.2 Using the Simulator

13. TCP / IP Communications 282 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 13.4 TCP/IP Example This example shows how to configure 2 PCs runni

Page 226

14. ECP Motion EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 283 14. ECP Motion 14.1 Overview An ECP (external control point) motion is when

Page 227

14. ECP Motion 284 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 14.1.1 How to move the arm with ECP motion In the following paragraphs, the pro

Page 228

14. ECP Motion EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 285 2. Teaching Teach the point data while moving the robot arm holding the actual

Page 229

14. Installing Controller Options 286 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 15. Installing Controller Options When you purchase options wi

Page 230

16. Software License Agreement EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 287 16. Software License Agreement THIS IS A CONTRACT. CAREFULLY

Page 231

16. Software License Agreement 288 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 PROTECTION AND SECURITY You agree not to deliver or otherwise mak

Page 232

Appendix A: Software Installation Appendix A: Software Installation EPSON RC+ 5.0 supports the following OS. Windows XP Professional Service Pack 3

Page 233

Appendix A: Software Installation 4. Click the Next button to continue. 5. Enter your user name and company name, then click Next. 6. Select th

Page 234

Appendix B: Project Import Automatic Processing Appendix B: Project Import Automatic Processing Project for EPSON RC+ 3.* / 4.* When projects created

Page 235

2. Safety EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 13 2.2.5 Changing Operation Mode You can change from AUTO operation mode or PROGRAM op

Page 236

Appendix B: Project Import Automatic Processing User Error Label File Conversion Files are changed automatically as the user error numbers are changed

Page 237

Appendix B: Project Import Automatic Processing Project Import for SPEL for Windows 2.* When projects created in SPEL for Windows 2.* are imported,

Page 238

Appendix B: Project Import Automatic Processing B-4 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Point File Conversion EPSON RC+ 5.0 .PTS files ar

Page 239

2. Safety 14 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 2.3 Safety-related Requirements Specific tolerances and operating conditions for safe

Page 240 - ◆ Layout Object

2. Safety EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 15 2.4 Installation and Design Precautions 2.4.1 Designing a Safe Robot System It i

Page 241

2. Safety 16 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Peripheral Equipment Design When designing equipment that removes and supplies parts an

Page 242

2. Safety EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 17 Safeguard System To ensure safety, a safeguard system should be installed for the ro

Page 243

2. Safety 18 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Resetting the Safeguard Ensure that the robot system can only be restarted through care

Page 244

2. Safety EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 19 Restarting after a Change When restarting the robot system after its hardware or soft

Page 245

2. Safety 20 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 2.5 Precautions regarding Robot Operation 2.5.1 General Precautions Before operati

Page 246

2. Safety EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 21 - If there is a possibility of a dangerous situation arising from the operation of a

Page 247

FOREWORD Thank you for purchasing our robot products. This manual contains the information necessary for the correct use of the Manipulator. Please c

Page 248

2. Safety 22 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 2.5.8 Backup of Projects and Controller After a project has been created or edited, or

Page 249

3. Getting Started EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 23 3. Getting Started This chapter contains instructions for setting up and us

Page 250

4. Operation 24 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 4. Operation This chapter contains instructions for operation of the EPSON RC+ 5.0

Page 251

4. Operation EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 25 Start Method 2 1. Click the Windows Start button. 2. Select the EPSON RC+ 5.0 Pr

Page 252

4. Operation 26 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 4.3.4 Start Mode Dialog When the start mode is set for Auto, then a dialog is displ

Page 253

4. Operation EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 27 4.3.6 Start Mode: Auto Auto mode displays the Operator Window. The Operator Win

Page 254

4. Operation 28 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 4.3.8 Windows Login You can configure automatic Windows login from EPSON RC+ 5.0.

Page 255

4. Operation EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 29 Change the EPSON RC+ 5.0 startup mode You can select the startup mode and override

Page 256

4. Operation 30 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 4.4 Communications with Controller Your PC running EPSON RC+ 5.0 can communicate w

Page 257

4. Operation EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 31 4.4.3 Ethernet Communications The robot controller does not support internet pro

Page 258

TRADEMARKS Microsoft, Windows, and Windows logo are either registered trademarks or trademarks of Microsoft Corporation in the United States and/or o

Page 259 - 9. Robot Configuration

4. Operation 32 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 This allows you leave the controller in Auto mode to monitor operation, or switch th

Page 260 - 9.2 Calibrating the Robot

4. Operation EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 33 4.5 Writing your first program After installing the Controller, robot, and EPSON

Page 261 - 9. Robot Configuration

4. Operation 34 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 4. Edit the program Type in the following program lines in the Program.prg edit wind

Page 262

4. Operation EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 35 (3) Click the Start button on the Run window to run the program. (4) You should

Page 263

4. Operation 36 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 (2) Click on the Motor On button to turn on the robot motors. You will be prompted

Page 264 - 10. Inputs and Outputs

4. Operation EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 37 8. Modify the program to change speed of robot motion commands (1) Insert the Pow

Page 265 - 10.5 Virtual I/O

5. The EPSON RC+ 5.0 GUI 38 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 5. The EPSON RC+ 5.0 GUI The chapter contains information on the EPSON

Page 266 - 11. Remote Control

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 39 5.2 Project Explorer Pane The Project Explorer pane enables you to qu

Page 267 - 11. Remote Control

5. The EPSON RC+ 5.0 GUI 40 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 5.4 Status Bar The status bar located at the bottom of the main window

Page 268

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 41 For MDI child windows, the Help button is located on the main toolbar

Page 269 - 11.7 Remote Inputs

MANUFACTURER Toyoshina Plant Factory Automation Systems Dept. 6925 Toyoshina Tazawa, Azumino-shi, Nagano, 399-8285 JAPAN TEL : +81-(0)263-72-

Page 270

5. The EPSON RC+ 5.0 GUI 42 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 5.6.2 Open Command (File Menu) Open one or more files in the current pr

Page 271 - 11.8 Remote Outputs

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 43 5.6.4 Save Command (File Menu) The Save command writes the current fi

Page 272

5. The EPSON RC+ 5.0 GUI 44 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 5.6.8 Rename Command (File Menu) Use Rename to change the name of the

Page 273

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 45 5.6.10 Import Command (File Menu) Import a file into the current pro

Page 274

5. The EPSON RC+ 5.0 GUI 46 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 5.6.11 Print Command (File Menu) This command opens the Print dialog b

Page 275 - 11.10 Remote Ethernet

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 47 5.6.12 Exit Command (File Menu) Exits from EPSON RC+ 5.0. If you ar

Page 276

5. The EPSON RC+ 5.0 GUI 48 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 5.7.5 Paste Command (Edit Menu) Puts the contents of the Clipboard int

Page 277 - Remote command

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 49 5.7.7 Find Next Command (Edit Menu) Find the next occurrence of the

Page 278

5. The EPSON RC+ 5.0 GUI 50 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 5.7.9 Select All Command (Edit Menu) Select the entire file. You can

Page 279

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 51 5.8 View Menu The EPSON RC+ 5.0 View Menu includes commands for open

Page 280

Southeast Asia EPSON Singapore Pte Ltd. India Factory Automation System 1 HarbourFrontPlace, #03-02 HarbourFront Tower one, Singapore 098633 T

Page 281 - Response

5. The EPSON RC+ 5.0 GUI 52 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 5.8.3 System History Command (View Menu) This command opens the System

Page 282

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 53 5.9 Project Menu The EPSON RC+ 5.0 Project Menu includes commands fo

Page 283 - Error response

5. The EPSON RC+ 5.0 GUI 54 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 5.9.2 Open Command (Project Menu) Use this command to open an EPSON RC

Page 284 - 11.11 Remote RS232

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 55 5.9.3 Recent Projects Submenu (Project Menu) The Recent Projects sub

Page 285

5. The EPSON RC+ 5.0 GUI 56 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 To add an existing program source file 1. Select the program name you wa

Page 286

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 57 5.9.6 Save Command (Project Menu) This command saves all currently o

Page 287

5. The EPSON RC+ 5.0 GUI 58 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 5.9.8 Rename Command (Project Menu) This command renames the current p

Page 288

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 59 5.9.9 Import Command (Project Menu) The Project Menu Import Command

Page 289

5. The EPSON RC+ 5.0 GUI 60 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 3. Select the project type. You can select from the following: - Epson

Page 290

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 61 Importing a Controller project For projects using Vision Guide, the ca

Page 291

vi EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4

Page 292

5. The EPSON RC+ 5.0 GUI 62 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 4. Verify the import source, import project, and destination project. C

Page 293

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 63 3. Select a controller status folder and click OK. 4. The destinat

Page 294 - Communication sequence

5. The EPSON RC+ 5.0 GUI 64 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 5.9.10 Copy Command (Project Menu) The Copy command copies all files i

Page 295 - 12. RS-232 Communications

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 65 5.9.11 Delete Command (Project Menu) This command deletes an entire

Page 296 - 12.2 RS-232 Commands

5. The EPSON RC+ 5.0 GUI 66 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 5.9.14 Synchronize Command (Project Menu) The Synchronize command is u

Page 297 - 13. TCP / IP Communications

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 67 5.9.15 Properties Command (Project Menu) Project: Properties: Genera

Page 298

5. The EPSON RC+ 5.0 GUI 68 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Project: Properties: Compiler Page This page allows you to configure the

Page 299 - 13.3 TCP/IP Commands

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 69 Project: Properties: Operator Settings : Operator Window: General Page

Page 300 - 13.4 TCP/IP Example

5. The EPSON RC+ 5.0 GUI 70 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Project: Properties: Operator Settings : Operator Window: Controls Page

Page 301 - 14. ECP Motion

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 71 Project: Properties: Operator Settings: Robot Manager Page Use this pa

Page 302

Table of Contents TABLE OF CONTENTS 1. Introduction 1 1.1 Welcome to EPSON RC+ 5.0 ... 1 1

Page 303 - 14. ECP Motion

5. The EPSON RC+ 5.0 GUI 72 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Project: Properties: Operator Settings: I/O Monitor Page Use this page t

Page 304

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 73 Project: Properties: Vision The EPSON Smart Camera supports two visio

Page 305

5. The EPSON RC+ 5.0 GUI 74 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 5.10 Run Menu The EPSON RC+ 5.0 Run Menu includes commands for running

Page 306

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 75 5.10.4 Step Over Command (Run Menu) Execute the current source line.

Page 307

5. The EPSON RC+ 5.0 GUI 76 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 5.10.8 Toggle Breakpoint Command (Run Menu) Sets the current line as a

Page 308

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 77 The Preserved page displays the Global Preserve variables. The numbe

Page 309 - I/O Label File Conversion

5. The EPSON RC+ 5.0 GUI 78 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 5.11 Tools Menu EPSON RC+ 5.0 has several GUI tools to aid in developm

Page 310

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 79 Tools: Robot Manager: Control Panel Page The Control Panel page contai

Page 311

5. The EPSON RC+ 5.0 GUI 80 EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 Tools: Robot Manager: Jog and Teach Page The Jog & Teach page is pri

Page 312 - Local Variable Conversion

5. The EPSON RC+ 5.0 GUI EPSON RC+ 5.0 (Ver.5.4) User's Guide Rev.4 81 Speed The speed for jogging and motion commands can be changed by sele

Commentaires sur ces manuels